午夜一级艳片欧美精品-麻豆传煤入口免费进入20212-欧美一级黄片免费观看-日韩制服诱惑一区二区三区

ECTDS10-ISO Isolated Solution Conductivity Transmitter/Sensor

Product Description:Name:ECTDS10-ISO Isolated Solution Conductivity Transmitter/SensorType:ECTDS10-ISOECTDS10 measures Conductivity, Salinity, TDS with temperature compensation.The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial,water processing, sewerage system, irrigation, smart agriculture etc.■ Conductivity, Salinity and TDS measurement with temperature compensation
Description

Product Description:

Name:ECTDS10-ISO Isolated Solution Conductivity Transmitter/Sensor

Type:ECTDS10-ISO

ECTDS10 measures Conductivity, Salinity, TDS with temperature compensation.

The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial,

water processing, sewerage system, irrigation, smart agriculture etc.

■ Conductivity, Salinity and TDS measurement with temperature compensation

■ Isolated Sensor Input

■ With ABS or Stainless steel electrode

■ Output Interface with RS485, Voltage, Current

■ High accuracy with excellent stability

■ Reverse power protection and Built-in TVS/ESD protection


Specifications

Output Interface

Analog Voltage 0-2V        

(Output resistance ~0ohm)

Analog Current 4-20mA        

(Load Resistor<500ohm)

RS485        

Modbus-RTU

Power Supply

3.9-30V/DC

12-30V/DC

3.9-30V/DC

Power Consumption(Idle)

40mA@24V DC

40mA@24V DC        

(with 20mA output signal)

40mA@24V DC

Power Consumption(Max)

80mA@24V DC

100mA@24V DC        

(with 20mA output signal)

80mA@24V DC

Start-up time

< 2 seconds

EC Measurement

Isolated Sensor Input, Range: 0-5000us/cm, 10000us/cm, 20000us/cm        Resolution: 0-10000us/cm, 10us/cm; 100000-20000us/cm, 50us/cm

Accuracy: 0-10000us/cm, ±3%; 10000-20000us/cm, ±5%

EC temperature compensation: 0-50°C

Temperature Measurement

Range: -40~80°C, Resolution:0.1°C, Accuracy:±0.5°C

IP Ratings

Electrode:IP68; Transmitter:IP65

Operating Temperature

-40~85°C

Installation

Electrode:1/2″NPT screw threads; Transmitter:Mounting hole

Cable Length

Power and Signal Cable:2 meters or Customize; Electrode Cable:5 meters

Dimension

Electrode:1/2″NPT screw threads; Transmitter:128*70*42mm


Ordering Information


Parameters

Code

Comments

Code 1:        

Product Series

ECTDS10-ISO

ECTDS10-ISO isolated conductivity transmitter

Code 2:        

Measuring Parameters

A

Conductivity, Salinity and TDS

Code 3:        

Electrode

A        

B

C

ABS electrode        

Stainless steel electrode

Customize

Code 4:        

EC Range

A        

B

C

D

E

0-20000us/cm        

0-10000us/cm

0-5000us/cm

0-2000us/cm

Customize

Code 5:        

Power Supply

A        

B

3.9-30V DC (applicable for RS485 and 0-2V output)        

12-30V DC (applicable for 4-20mA output)

Code 6:        

Output Interface

A        

B

C

D

E

F

G

Analog Voltage 0-2V        

Analog Current 4-20mA

RS485,Modbus-RTU

RS485,Modbus-RTU & Analog Voltage 0-2V

RS485,Modbus-RTU & Analog Current 4-20mA

SDI-12

Customize

Code 7:        

Cable Length

002        

XXX

Electrode Cable:5 meters , Power and Signal Cable:2 meters        

Electrode Cable:5 meters , Power and Signal Cable:xxx meters

Ordering Code Example:        

ECTDS10-ISO isolated conductivity transmitter, ABS electrode, Conductivity Range 20000us/cm, Power Supply 3.9-30V DC, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ECTDS10-ISO-A A A A C 005

1.jpg


2.jpg